News

TOC Analysers for IECEx and ATEX zones

Total Organic Carbon analysers are commonly used to measure the level of organic contamination in water. Online TOC analysers installed in refineries and petrochemical plants are located right in the middle of the process facilities.

Picture of a Technician working on a TOC Analyser

Technician working on a TOC Analyser

Picture of a XY and a loop injection system

Close up picture of the XY and loop injection systems

Picture of a total organic carbon analyser in an ex-zone housing

Total organic carbon analyser QuickTOCultra in an ex-zone housing

Total Organic Carbon analysers are commonly used to measure the level of organic contamination in water. Online TOC analysers installed in refineries and petrochemical plants are located right in the middle of the process facilities. Here explosive gasses, vapours or mist can be present. It is a high risk situation, as any spark or any heat source may cause an explosion. Hence, explosive areas necessitate safety protection measures in order to ensure high labor safety as well as operational safety.

LAR Process Analysers, Germany, offers with its online TOC analysers QuickTOCultra and QuickTOCpurity stand-alone measuring equipment with explosion-proof housings certified according to the latest ATEX and IECEx standards (EN 60079-2:2011-11 and IEC 60079-14:2007). LAR's custom-fit analysers come with stainless steel housings with over pressure encapsulation and purging system (Ex p) that do not require air-conditioned shelters, providing an easier way to maintain and operate the measurement systems. LAR’s stand-alone TOC analysers correspond to requirements of ATEX Zone 1 and Zone 2 (T3/T4) as well as in IECEx Zone 1 T4.

Application-specific injection system

Depending on the water to be tested, LAR offers custom-fit analysers for every measurement task. The QuickTOCpurity is especially designed for pure water applications (steam/ condensate return, boiler feed water, cooling water). The analyser is equipped with a closed injection loop where a subset of a water sample is injected into the furnace. Thus, contamination of the sample by substances in the ambient air is avoided. In addition, VOC and POC (volatile/purgeable organic carbon) are not released and hence, are included in the measurement. The process control of the TOC system is an advantage, especially in chemical and petrochemical plants, in which various substances can be present in the air.

LAR’s QuickTOCultra is designed for complex water compositions. The measurement system is equipped with a robotic, horizontally and vertically moving injection needle that imitates the laboratory injection process. The injection system is capable of transporting and measuring a high content of solid matter without any filtration of the sample. The QuickTOCultra easily handles sticky, fatty, salty, and high-particle samples unlike other TOC analysers.

Ultra high temperature combustion

The furnace is the centerpiece of LAR’s TOC analysers. They use the patented high-temperature combustion method at 1200°C guaranteeing the complete digestion of all carbon compounds in the sample to CO2. Oxidation promoting catalysts, such as those used in other measuring methods, are unnecessary. As a consequence, the operating costs of the measurement system are minimized. Downstream of the furnace, the formed CO2 will be measured by a NDIR detector resulting in the exact determination of TOC. LAR's analysers determine the TOC in less than three minutes and thus, allows the operators to take fast countermeasures in case of water pollution.

Both TOC analysers are designed for the measurement of up to six sample streams in one device. Each sample stream can have different combinations of parameter such as TOC, TC, TIC, COD and/or TNb. Various process streams can so easily be monitored in a single analyser. The TOC analysers are controlled via a 10.4“ touchscreen display. Access to the measuring system can even be done via internet protocol for example from a control room.

LAR’s custom-fitted TOC analysers take care of the concrete challenges of pure water and waste water applications minimizing maintenance efforts and making the optimization and control of complex processes possible.

 

Would you like to learn more about the TOC analyser? Contact us directly here.

Contact us here

 

 

Der gesamte organische Kohlenstoff (engl. total organic carbon, kurz: TOC) ist einer der wichtigsten Summenparameter für die Beurteilung der organischen Belastung eines Wassers. Da alle organischen Kohlenstoffverbindungen als Masse Kohlenstoff erfasst und angegeben werden, ist der TOC eine exakt definierbare, absolute Größe und direkt messbar.

Erfahren Sie mehr über TOC Messmethoden.

TOC Messgeräte der LAR Process Analysers AG

Der chemische Sauerstoffbedarf (CSB) kennzeichnet die Menge an Sauerstoff, die zur Oxidation der gesamten im Wasser enthaltenen organischen Bestandteile verbraucht wird und ist damit ein wichtiger Indikator für die Abwasseranalyse. Er wird zur Planung, Steuerung und Reinigungseffizienz betrachtet und ist Grundlage für Kalkulationen der Abwasserentgelte.

Der CSB-Gehalt lässt sich im Labor oder online bestimmen, wobei sich die einzelnen Methoden stark in ihrer Dauer und den zu verwendenden Verbrauchsmaterialien unterscheiden.

Erfahren Sie mehr über Methoden der CSB-Bestimmung.

CSB-Messgeräte der LAR Process Analysers AG

Der biochemische Sauerstoffbedarf (BSB) kennzeichnet die Menge an Sauerstoff, der zum biologischen Abbau organischer Verbindungen im Abwasser benötigt wird.

Da der überlicherweise verwendete BSB5 den Abbau von Stickstoff-Verbindungen nicht berücksichtigt (Nitrifikation), eignet sich der Parameter nur unzureichned zur Steuerung und Optimierung von Kläranlagen. Da der Gesamt-BSB den Abbau von Stickstoff- als auch Kohlenstoffverbindungen betrachtet, eignet sich> dieser Parameter hervoragend als Alternative zum BSB5.

Erfahren Sie mehr über die Online BSB-Messung.

Als Toxizität (Giftigkeit) bezeichnet man die direkte schädliche Wirkung von Substanzen auf Organismen. Die toxische Wirkung hängt von der Schadstoff-Konzentration, von der Empfindlichkeit der Organismen sowie von der Inkubationszeit ab. Schon bei geringen Konzentrationen kann diese auftreten.

Es existieren verschiedene Verfahren zur Bestimmung der Toxizität. Es können jedoch keine Aussagen in Bezug auf die Art der Toxizität getroffen werden, sondern lediglich, dass Toxizität vorliegt. Die Verfahren testen an Fischen, Daphnien, Muscheln, Algen oder Bakterien, ob eine Wasserprobe toxische Effekte bei den Organismen auslöst oder nicht.

Erfahren Sie mehr über die Online Toxizitätsmessung.

BSB-Messgerät und Toxizitätsmessgerät der LAR Process Analysers AG

Der gesamt gebundene Stickstoff (engl. total nitrogen bound, kurz: TNb) spiegelt die Belastung des Wassers mit Stickstoffverbindungen wider. Stickstoff kann in Form von Ammoniak, Ammoniumsalzen, Nitriten, Nitraten und organischen Stickstoffverbindungen vorkommen.

Im Gegensatz zu den Einzelbestimmungen der genannten Komponenten erfasst die TNb-Messung alle Komponenten in einem Analysegang.

Erfahren Sie mehr über die Online TNb-Messung.

Der Gesamtphosphor (TP) ist ein Summenparameter, der organische und anorganische Phosphorverbindungen im Wasser widerspiegelt. Phosphor ist essentieller Nährstoff für Mensch und Natur, jedoch kann die Substanz je nach Konzentration zu schwerwiegenden Schäden führen.

Erfahren Sie mehr über die Online TP-Messung.

TN TP Analysatoren der LAR Process Analysers AG